Application:
The KWD iron boilers - Camino 3 are designed to heat single- and two-family houses, flats, small supermarkets, shops, offices, etc. Central heating systems for the boilers shall be made in accordance with PN-91/B-02413, that is as open systems with equalizing vessels. The basic fuel is domestic coke of so called „Nut I” type of calorific value 25113 kJ/kg. As a replacement fuel other types of domestic coke, blast-furnace coke or coke and coal 1:1 mixtures can be used. The boilers can operate in gravity system with upper or lower, forced (pump) distribution and can be used in installations of warm usable water preparation.
Advantages:
They are low-temperature boilers and as such they do not require to be registered by Technical Inspection Agency. Durability of the pressure parts of boilers meets the requirements of BN-76/1317-04 and should not be shorter than 10 years provided that boilers are operated properly. The required size of chimney draught should ensure connection of boiler to a chimney min. 8 m high and cross-section area 20x20 cm minding that connection of boiler should be as short as possible. The KWD Camino 3 boilers have upper and side shell, they are painted and insulated by means of mineral plate. The boilers are also equipped with servicing tools.
Technical specifications:
| Size of KWD-Camino boiler | |||||||
|---|---|---|---|---|---|---|---|
|
Unit |
3/4 |
3/5 |
3/6 |
3/7 |
3/8 |
3/9 | |
| Number of boiler units |
pcs |
4 |
5 |
6 |
7 |
8 |
9 |
| Heating surface |
m2 |
0,7 |
0,9 |
1,1 |
1,3 |
1,5 |
1,7 |
| Nominal calorific effect |
kW |
9,77 |
12,56 |
15,35 |
18,14 |
20,93 |
23,73 |
|
Mcal/h |
8,4 |
10,8 |
13,2 |
15,8 |
18 |
20,4 | |
| Max. working pressure of water |
PA |
1,72x105 | |||||
|
atm |
1,7 (17m H2O) | ||||||
| Max. working temperature of water |
OK |
373 | |||||
|
OC |
100 | ||||||
| Optimum thermal efficiency |
η% |
77,8 | |||||
| Chimney draught |
Pa |
11 |
14 |
16 |
18 |
21 |
25 |
|
mm H2O |
1,1 |
1,4 |
1,6 |
1,8 |
2,1 |
2,5 | |
| Dimension L |
mm |
295 |
370 |
445 |
520 |
595 |
675 |
| Weight of boiler |
kg |
144 |
170 |
196 |
222 |
248 |
274 |
| Boiler’s water capacity |
dcm3 |
25 |
29 |
33 |
37 |
41 |
45 |
| Name of part or unit | No. of unit, part or standard | pcs/boiler with number of units | |||||
|---|---|---|---|---|---|---|---|
| 4 | 5 | 6 | 7 | 8 | 9 | ||
| Front unit |
K 84-1-12 |
1 | |||||
| Intermediate unit |
K 75-1-13 |
1 | |||||
| Central unit |
K 75-1-14 |
1 |
2 |
3 |
4 |
5 |
6 |
| Rear unit |
K 84-1-15 |
1 | |||||
| Adapter 48 |
BN-71/1317-03 |
6 |
8 |
10 |
12 |
14 |
16 |
| Boiler’s shell |
K 72-1A/II |
1 | |||||
| Charging door |
PK-02.30 |
1 | |||||
| Ash pit door |
PK-02.40 |
1 | |||||
| Cleaning plates |
K 72-1N1/I |
1 | |||||
| Smoke conduit |
K 74-1F/III |
1 | |||||
| Pre-furnace grate |
K 69-1G/II |
1 | |||||
| Temperature controller |
PN/M-35811 |
1 | |||||